How to connect a PT100 or PT1000 to a Fly-SHT36 Max V3

Overview

The Fly-SHT36 Max V3 toolboards have support for PT100 and PT1000 temperature sensors.
For PT1000, you can either use this connection method described here or the standard temperature sensor connector with a jumper installed as described on the general information page.

Hardware Setup

The use of PT100 and PT1000 temperature sensors is setup using the 8 dip switches on the Fly-SHT36 Max V3.
Use the image below to setup the jumpers on the 8 dip switches according to the type of PT100 or PT1000 temperature sensors you are connecting.

Fly-SHT36 Max V3 DIP Switches
Fly-SHT36 Max V3 DIP Switches

Config.g changes

PT100

To use the PT100 on your hotend, use the following code in config.g If you are in a country where the mains frequency is 50Hz, change the F60 to F50 (if you don’t know, look here)

M308 S1 P"124.max31865cs" Y"rtd-max31865" F60 R430 W#

PT1000

To use the PT1000 on your hotend, use the following code in config.g If you are in a country where the mains frequency is 50Hz, change the F60 to F50 (if you don’t know, look here)

M308 S1 P"124.max31865cs" Y"rtd-max31865" F60 R430 W#
Tags: